Switching Power Supply
|
Model
|
NES-350-24
|
Output
|
DC Voltage
|
24V
|
Rated Current
|
14.6A
|
Current Range
|
0 ~ 14.6A
|
Rated Power
|
350.4W
|
Ripple & Noise (Max.) *Note.2
|
150m Vp-p
|
Voltage ADJ. Range
|
17.8 ~ 28V
|
Voltage Tolerance *Note.3
|
±1.0%
|
Line Regulation *Note.4
|
±0.5%
|
Load Regulation *Note.5
|
±0.5%
|
Setup, Rise Time
|
1000ms, 50ms/230VAC
1000ms, 50ms/115VAC at full load
|
Hold Up Time (typ.)
|
20ms/230VAC
16ms/115VAC at full load
|
Input
|
Voltage Range
|
90 ~ 132VAC / 180 ~ 264VAC by switch
254 ~ 370VDC
|
Frequency Range
|
47 ~ 63Hz
|
Efficiency (typ.)
|
87%
|
AC Current (typ.)
|
7A/115VAC
4A/230VAC
|
Inrush Current (typ.)
|
40A/115VAC
60A/230VAC
|
Leakage Current
|
<3.5mA / 240VAC
|
Protection
|
Overload
|
105 ~ 135% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
Over Voltage
|
27.6 ~ 32.4V
|
Protection type : Shut down O/P voltage, re-power on to recover
|
Over Temperature
|
90ºC + 5ºC (3.3 ~ 7.5V); 85ºC + 5 ºC (12 ~ 15V);
80ºC + 5ºC (24V); 75ºC + 5ºC (27 ~ 48V) (TSW1) Detect on case
|
Protection type : Shut down O/P voltage, recovers automatically after temperature goes down
|
Function
|
Fan ON/ OFF Control (typ.)
|
RTH2 > 50ºC FAN ON, < 45ºC FAN OFF (3.3 ~ 7.5V)
|
RTH2 > 55ºC FAN ON, < 50ºC FAN OFF (12 ~ 48V)
|
Environment
|
Working Temp.
|
-20 ~ +60 ºC (Refer to output load derating curve
|
Working Humidity
|
20 ~ 90% RH non-condensing
|
Storage Temperature, Humidity
|
-20 ~ +85 ºC , 10 ~ 95% RH
|
Temp. Coefficient
|
±0.03%/ ºC (0 ~ 50 ºC)
|
Vibration
|
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
Safety & EMC (note 6)
|
Safety Standards
|
UL60950-1 approved
|
Withstand Voltage
|
I/P-O/P:3KVAC
I/P-FG:2KVAC O/P-FG:0.5KVAC
|
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ºC / 70% RH
|
Others
|
MTBF
|
234.3Khrs min. MIL-HDBK-217F (25ºC) |
Dimension – RS-35 (L x W x H)
|
8.46 x 4.52 x 1.96 Inch / 215 x 115 x 50 mm |
Weight
|
1Kg; 12pcs/13.5Kg/0.92CUFT
|
Note
|
1. A parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Please connect positive pole of input voltage with mark “N” of terminal block, connect negative pole of input voltage with mark “L” of terminal block, using DC voltage for input voltage.
|