Switching Power Supply with Steel Enclosure
|
Model
|
RS-100-24
|
Output
|
DC Voltage
|
24V
|
Rated Current
|
4.5A
|
Current Range
|
0 ~ 4.5A
|
Rated Power
|
108W
|
Ripple & Noise (Max.) *Note.2
|
120m Vp-p
|
Voltage ADJ. Range
|
21.7 ~ 27.5V
|
Voltage Tolerance *Note.3
|
±1.0%
|
Line Regulation *Note.4
|
±0.5%
|
Load Regulation *Note.5
|
±0.5%
|
Setup, Rise Time
|
500ms, 30ms/230VAC
1200ms, 30ms/115VAC at full load
|
Hold Up Time (typ.)
|
100ms/230VAC 18ms/115VAC at full load
|
Input
|
Voltage Range
|
88 ~ 264VAC
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
|
Frequency Range
|
47 ~ 63Hz
|
Efficiency (typ.)
|
84%
|
AC Current (typ.)
|
2A/115VAC 1.2A/230VAC
|
Inrush Current (typ.)
|
Cold Start 40A/230VAC
|
Leakage Current
|
<2mA / 240VAC
|
Protection
|
Overload
|
110 ~ 150% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
Over Voltage
|
27.6 ~ 32.4V
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
Environment
|
Working Temperature
|
-25 ~ +70 ºC (Refer to "Derating Curve")
|
Working Humidity
|
20 ~ 90% RH non-condensing
|
Storage Temperature, Humidity
|
-40 ~ +85 ºC, 10 ~ 95% RH
|
Temp. Coefficient
|
±0.03%/ ºC (0 ~ 50 ºC)
|
Vibration
|
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
Safety & EMC (note 6)
|
Safety Standards
|
UL60950-1, TUV EN60950-1 approved
|
Withstand Voltage
|
I/P-O/P:3KVAC
I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ºC / 70% RH
|
EMC Emission
|
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
|
EMC Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level,
criteria A
|
Others
|
MTBF
|
249Khrs min.
MIL-HDBK-217F (25ºC)
|
Dimension – RS-35 (L x W x H)
|
6.25 x 3.81 x 1.49 Inch / 159 x 97 x 38 mm |
Weight
|
4.6 LBs
|
Note
|
1. A parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMl testing of component power supplies.”(Available on http://www.meanwe.com) |