Specification of VDS2700-R Sender
To ensure smooth operation of VDS2700-R Sender, the following minimum system and setup requirements should be met.
| Model |
VDS2700-R Sender |
| Electrical |
| Video, Audio and Alarm |
Video Input Signal: |
1.0Vpp, 75Ω |
| Bandwidth of Video Signal: |
5.5MHz typ |
| Audio input Signal: |
3.0Vpp, max 100K ohms/ Internal Impedance. |
| Alarm Input type: |
N.C./N.O./Terminator 1,000Ω |
| DC Power and Link Out |
Power Output: |
DC12V, 1.0 A, max. |
| RS-485 Data Rate: |
DC (0bps) to 38.4Kbps |
| Connection: (PTB= Plugable Terminal Block) |
| PTB |
Video Input: |
BNC Socket |
| Audio Input: |
BNC Socket/RCA Phono Socket Optional |
| DC and Alarm: |
4 Pin PTB, 3.5mm Pitch |
| RS-485 Port: |
3 Pin PTB, 3.5mm Pitch |
| Link Out: |
BNC Socket |
*Specifications are subject to change without notice.
MADE IN TAIWAN
Specification of VDS2700-L Viewer
To ensure smooth operation of VDS2700-L Viewer, the
following minimum system and setup
requirements should be met.
| Model |
VDS2700-L Viewer |
| Electrical |
| Video, Audio and Alarm |
Video Output Signal: |
1.0Vpp, 75Ω |
| Bandwidth of Video Signal: |
5.5MHz typ |
| S/N ratio of Video Signal: |
50dB typ |
| Gain of Audio signal Output: |
0dB ±3dB, 600Ω / internal impedance |
| Bandwidth of Audio Signal: |
50Hz to 10KHz ±3dB |
| S/N Ratio of Audio Signal: |
46dB under 1.0Vpp input at RU |
| Alarm Output: |
N.C./N.O., Contact Rating 1A, 30VDC Dry contact |
| DC Power and Link Out |
DC Power Input: |
40V |
| Max. DC power Output: |
38V, 1.4A, min. |
| Link Fault Output: |
0.15A, min. |
| RS-485 Data Rate: |
DC(0bps) to 38.4Kbps |
| Connection: (PTB= Plugable Terminal Block) |
| PTB |
Link In: |
BNC Socket |
| Link Fault: |
3 Pin PTB, 3.5mm Pitch |
| DC Power Input: |
2 Pin PTB, 5.0mm Pitch |
| Video Output: |
BNC Socket |
| Audio Output: |
BNC Socket/RCA Phono Socket Optional
or auxiliary video output on VDS2744 |
| Alarm Output: |
3 Pin PTB, 3.5mm Pitch |
| RS-485 Port: |
3 Pin PTB, 3.5mm Pitch (2 Set) |
*Specifications are subject to change without notice.
MADE IN TAIWAN
- VDS2700-R Sender (Remote Unit)
-
VDS2700-L Viewer (Local Unit)
-
Power supply (AC to DC power adapter) and power cord
-
Four mounting brackets and four screws
-
Two 120 ohms terminators for Rs485 daisy chain. One for Remote unit and
the other for RS485 Network in Local side.
-
One 1,000 ohms terminator for Terminator Mode use in Alarm Input side.
-
Installation Manual
*Eighteen (18) months Manufacturer's Limited Warranty
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Transmit real-time analogue video signals.
-
Compact size, durable and reliable device.
-
Built-in electrical transient voltage suppressor protection in the input and output.
-
Using 5C-2V (Japan spec) coaxial cable can transmit 12V DC power to P/T/Z camera via one coaxial cable with a distance up to 2000Ft / 600M (distance can reach up to 3200Ft / 1000M without sending DC power to camera).
|
|
 |
 |
 |
 |

|